Cable Catalog

Can't find what you need? We'll build it for you.
Catalog Home
Hook-Up Wire
90°C
300 volts
105°C
125°C
Low Voltage
600 volts
150°C
200°C
300 volts
600 volts
450°C
Welding
CLASS K
CLASS M
Multi-Conductor
Unshielded
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Foil Shield
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Braid Shield
Foil/Braid Shield
Standard
Low capacitance
Thermostat
LVT
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
FAT
Data & Communication
Outdoor
Station Z
Solid
Shielded
Unshielded
Stranded
Unshielded
CAT 3
Solid
Shielded
Unshielded
CAT5e
Solid
Shielded
Unshielded
CAT6
Solid
Unshielded
Non-Plenum (FT4)
CAT 3
Solid
Shielded
Unshielded
CAT6a
Solid
Shielded
Unshielded
Station Z
Solid
Unshielded
Intercom
Solid
Unshielded
CAT5e
Solid
Unshielded
CAT6
Solid
Unshielded
Plenum (FT6)
Station Z
Solid
Unshielded
CAT 3
Solid
Unshielded
CAT5e
Solid
Unshielded
CAT6
Solid
Unshielded
L.S.Z.H.
CAT 6
Solid
Unshielded
Fire Alarm Signal
FAS Unshielded
FAS Shielded
FAS Unshielded & Armored
FAS Shielded & Armored
Multi-Pair
Unshielded
Non-Plenum (FT4)
Plenum (FT6)
Shielded
Non-Plenum (FT4)
Overall Foil Shield
Standard
Low Capacitance
Individual Foil Shield
Standard
Low Capacitance
Braid & Individual Foil Shield
Low Capacitance
Foil & Braid Shield
Standard
Low Capacitance
Plenum (FT6)
Overall Foil Shield
Standard
Low Capacitance
Individual Foil Shield
Standard
Low Capacitance
Foil & Braid Shield
Coaxial
Indoor
FT4
FT6
Outdoor
Direct Burial
Aerial
FT1
FT4
Building Automation
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Composites
Datacom
Fiber Optic
Single mode
8,3
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Loose Tube
Outdoor
Multimode
50/125
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
62,5/125
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Loose Tube
Outdoor
2-Hour Fire Rated
Power Cable
Standard
L.S.Z.H.
Approved accessories
FAS
Armored
Shielded
Unshielded
Jacketed
Transit
Power
Mono-conductor
Multi-conductor
Communications
Multi-conductor
Shielded
Unshielded
Multi-pair
Shielded
Unshielded
Emergency circuit
Solar
 
Part # Search
 
Advanced search
Enter criteria

 
Need help?

Ask the Cable Guru

Building Automation & Control

Non-Plenum (FT4)
 
8202 shot
Application
Building Automation - HVAC
Control
 
Conductors  
 
Part #Conductor(s)Jacket thicknessSize (AWG)Armor diameterOverall Diameter
820240.51 mm18 AWGn/a5.33 mm
824240.38 mm22 AWGn/a4.14 mm
Pairs  
 
Part #Pair(s)Jacket thicknessSize (AWG)Armor diameterOverall Diameter
81801n/a14 AWGn/a6.81 mm
82171n/a16 AWGn/a5.82 mm
819010.58 mm16 AWGn/a6.25 mm
820010.51 mm18 AWGn/a4.75 mm
821010.51 mm18 AWGn/a4.52 mm
821220.58 mm18 AWGn/a6.88 mm
822010.38 mm20 AWGn/a3.71 mm
822220.38 mm20 AWGn/a3.86 mm
822410.38 mm20 AWGn/a4.01 mm
822910.38 mm22 AWGn/a3.1 mm
823010.64 mm22 AWGn/a3.94 mm
823330.58 mm22 AWGn/a5.66 mm
824010.46 mm22 AWGn/a3.61 mm
824710.76 mm22 AWGn/a4.37 mm
825010.76 mm24 AWGn/a4.12 mm
825120.76 mm24 AWGn/a5.74 mm
82534n/a24 AWGn/an/a
825460.76 mm18 AWGn/a11.02 mm
Triads  
 
Part #Triad(s)Jacket thicknessSize (AWG)Armor diameterOverall Diameter
819110.58 mm16 AWGn/a6.1 mm
820110.51 mm18 AWGn/a4.75 mm
821110.51 mm18 AWGn/a4.8 mm
822110.38 mm20 AWGn/a3.94 mm
823110.76 mm22 AWGn/a4.45 mm
824110.64 mm22 AWGn/a3.81 mm
824810.76 mm22 AWGn/a5.11 mm
Units:  
The values shown are nominal.