2-Hour Fire Rated
Power Cable

VitaLink

When you need the absolute best.

ULC - 2 hour fire rating
Fast and easy installation and termination
Horizontal and vertical installations


VITALink® RC90 is a self-contained 2-hour fire rated cable system that offers cost, reliability and ease of installation advantages over other methods of providing Fire Rated Circuits.

It is CSA Listed as Type RC90 and Certified to ULC S139 “Tests for Fire Resistive Cables”. This cable system meets* the code requirements for 2 hour Fire Rated Circuits, Electrical Circuit Protective Systems, Survivability or Circuit Integrity as applicable. We equally have Canadian approval for the FHIT7 120A and FHIT7 60 & 60A. This cable meets the National Building Code of Canada's section 3.2.7.10 requirements and is compliant with the Canadian Electrical code.
VIEW FULL SPECS

PRODUCT BROCHURE   INSTALLATION MANUAL
Cable Shot
ULC S139 with hose stream
90°C, 600 Volt CEC Type RC90 CSA Listed
UL/ULC Electrical Circuit Integrity System (FHIT7 120)
 
* must be installed per the Canadian Electrical Code, manufacturer’s install instructions and the qualification criteria of ULC Electrical Circuit Integrity System FHIT7 120

2-hour fire protection without compromise.

Specifically designed, easy to use hardware
The equipment grounding copper sheath is terminated with a readily available brass connector (multiple sources) and the cable connections are made without the need for splicing or special tools. When compared to Mineral Insulated (MI) cable, VITALink RC90 is not exposed to costly field expenses in preparing cable ends, special panel penetrations, additional flexible terminations and the splicing of shorter lengths in longer runs. VITALink RC90 is not susceptible to voltage failures caused by moisture ingress through leaky seals or faulty storage.

The right choice for the required protection
Alternate methods such as installation in isolated service spaces, most of the time, is and expensive and inefficient solution. It must be remembered that service spaces do not test the electrical capability of the circuit during or after a fire but only the structural ability to prevent fire spread.
Cable Shot

Features
  • 2-Hour Fire Rating per ULC S139 with hose stream, Horizontal Vertical applications
  • Simple termination, standard tools widely available brass connectors
  • Available in long lengths
  • Welded copper sheath suitable for equipment bonding per CEC rules 10-618 and 10-804
  • Welded copper sheath forms an impervious armor
  • Suitable for wet locations
Performance standards
  • CSA Listed type RC90 per CSA 22.2 No. 123
  • 2 Hour Fire Rating per ULC S139
  • Electrical Circuit Integrity System #120
  • (FHIT7) – ULC Canada
  • Wet location rating 90°C
  • Meets NFPA 130 for Transit and NFPA 502 for Tunnel applications
  • Single conductor ampacity when installed per CEC Table 1


Featured Projects

In collaboration with Canada's top electrical installers, Cerco Cable has provided a variety of cabling solutions for some of the country’s most important and iconic projects.
Crosslinx Eglinton Crosstown Tunnel
Immeuble Widson Montréal
Hôpital Enfant-Jésus de Québec
Palais de Justice de Rimouski
Tunnel Ville-Marie
Siège Social de la Gendarmerie Royale
Aéroport de Montréal
Holt Renfrew Ogilvy
Toronto Community Center
Colchester Est Hants Health Center
Vaughan Hospital
Devonshire Mall Windsor
Riocan Burlington Mall
Stade Olympique Montréal
Place Ville-Marie
Université de Montréal
Ottawa Art-Gallery
STM Garage Crémazie
Hôpital Sacré-Coeur de Montréal
Fairview Pointe-Claire
Ailes de la Mode Montréal
Hôpital Enfant-Jésus
Hôpital St-Francois d'Assie
Les Résidances des Îles

Questions? Need a quote?

Contact us, get a quick answer.