Transit Section
• Complete solutions for rail systems, metro, and urban transit offering enhanced fire safety and durability.
• Complete solutions for rail systems, metro, and urban transit offering enhanced fire safety and durability.
| Image | Product Name | Description |
|---|---|---|
|
The Connectors are Custom Fit to the Outer Diameter of the Armor. Optional Materials by Request: Stainless Steel, Nickel-Plated Brass | |
|
Tray cables encompass TC-ER rated products, typically 600V or 1000V power cables in single- or multi-conductor formats, often with FT4 or FT4-ST1 flame ratings for low-smoke options. | |
|
RW90 LSZH cables are available in 600V or 1000V ratings, in single- or multi-conductor configurations with various sizes. They feature cross-linked polyethylene (XLPE) insulation rated for 90°C wet or dry operation, combined with low smoke zero halogen jacketing and FT4-ST1 plus TC-ER ratings. | |
|
ACIC (Armored Control and Instrumentation Cable) is rated at 300V and commonly features shielded pairs or triads (e.g., 18 AWG tinned copper conductors). It is designed for reliable signal transmission in electrically noisy environments. | |
|
Teck LSZH cables are armored power cables rated at 1000V, available in multi-conductor configurations. They feature low smoke zero halogen jackets and meet stringent FT4-ST1 flame and smoke requirements. | |
|
Traction power cables are specialized single-conductor cables rated at 2000V, designed for railway and transit applications. These cables comply with CSA FT4-ST1 and TC-ER ratings, allowing exposed runs and installation in cable trays per Canadian Electrical Code requirements. | |
|
Temporary lighting for tunnels and many other applications. A lighting system that supports visual perception and consistent light levels. Ease of installation and overall cost savings. | |
|
The RTX is a heavy duty, harsh environment luminaire designed for rail and tunnel applications. Its 1? low-profile design enables RTX to be mounted to the tunnel wall using quick latch hangars or via snake rack and keeps the fixture out of the dynamic envelope. Push-and-click connectors make installation easy to terminate to any wiring box used in today’s tunnel environment. The innovative driverless technology is EMI-silent and connects directly to AC line voltage, providing extreme reliability and zero maintenance. | |
|
Snake Tray is a leading provider of cable management solutions for transit, tunnel and wayside environments. All Snake Tray products comply with NFPA 130 and NFPA 502 and are made in the USA. Our patented cable tray and racking systems are the solution for these applications. | |
|
NFPA 130 compliant patch cords, using HUB-Link® communications cables, are a plug and play solution that ensures reliable connections between critical equipment in transit systems to help keep passengers safe. Supporting contractors, installers and engineers, these patch cords are pre-assembled and pre-tested to save time and labor during installation. (Patch) | |
|
HUB-Link® Transit Communications NYCT Approved cables are ideal for the following applications: • Outside Plant Transit, Subways and Tunnels • Various Mass Transportation Facilities • Voice and Data Telephone Circuits • Installed in Pathways and Termination Closets (HT01) | |
|
HUB-Link® LSZH Telecommunication cables are ideal for the following applications: • Transit, Subways, Tunnels • Various Mass Transportation Facilities • Voice and Data (HT03) | |
|
HUB-Link® Case Wire cables are ideal for the following applications: • Bungalow Electronics Equipment • Trackside Applications • Relay & Signal Apparatus Wiring (HT05) | |
|
HUB-Link® LSZH Data Communications cables are ideal for the following applications: • Transit, Subways, Tunnels • Various Mass Transportation Facilities • Voice and Data (HT02) | |
|
HUB-Link® Signal cables are ideal for the following applications: • Transit Control Rooms & Operational Control Centers • Wayside, Tower, and Case • Trackside Signal Equipment (HT04) | |
|
Axle Counter Cables are designed to support Positive Train Control (PTC) & Communication Based Train Control (CBTC), contributing to the safety of personnel and assets. These devices rely on wired communication to centralized stations that relay information of transit activity. The Axle Counter Device monitors and counts the number of train axles passing by them. The HUB-Link Axle Counter Cable allows installation, with or without direct burial, that provides reliable communication potentially reducing installation cost. (HT06) | |
|
VITALink® RC90 is a 600V 2-hour fire rated cable listed to ULC S139 with hose stream. It is specifically designed to meet both the electrical and fireresistive cable requirements of NFPA 130 and NFPA 502 for emergency communications, emergency lighting & emergency ventilation. When installed per Systems FHIT7 120, 120A, and 60, plus the CEC, VITALink® RC90 meets code requirements for 2-hour Fire Rated Circuits, Electrical Circuit Integrity Systems, Survivability and Circuit Integrity. VITALink® RC90 Cables offer lowered cost, reliability and ease of installation advantages over MI cable and other methods of providing fire rated circuits. The equipment grounding copper armor is terminated with commercially available brass MC/RC connectors and the cable connections are made without the need for splicing or use of special tools. Compared to Mineral Insulated (MI) cable, VITALink® RC90 is not exposed to costly field expenses in preparing cable ends, special panel penetrations, additional flexible terminations, and the splicing of shorter lengths in longer runs. VITALink® RC90 is not susceptible to failures caused by moisture ingress through leaky seals or faulty storage. (VT03) | |
|
VITALink® Coax cables are engineered to provide superior performance for ERCES (Emergency Responder Communications Enhancement System), ensuring critical communication remains intact during emergencies. ERCES enables seamless wireless radio communication for first responders in tunnels, subway stations, and other transit spaces where reliable connectivity is essential. In fire conditions, traditional cables can suffer from increased signal loss, leading to dangerous communication failures. VITALink® Coax, enhanced with Aircell® technology, minimizes signal degradation and maximizes performance under extreme heat, reducing the risk of outages that could jeopardize emergency response efforts. Additionally, its unique design eliminates the need for conduit, offering unmatched installation flexibility while significantly lowering overall installation costs. VITALink® Coax delivers a superior fire-rated cable solution that enhances reliability, performance, and safety when it matters most. (VT04) | |
|
VITALink® Armored cables are ideal for: Low voltage critical circuits located in enclosed spaces or harsh environments, such as: • Transit Tunnels & Platforms • Underground & Below Grade Structures, e.g. Parking Garages • Petrochemical, Nuclear, & Waste Treatment Facilities • Commercial Retrofits with Non- UL 2196 Approved Conduit (VC07) | |
|
VITALink® 502 is an RHW-2/RW90 cable, which offers superior fire endurance capabilities along with the well-established benefits and features associated with NEC and CE Code Type RHW-2/RW90 cable designs. It is designed to meet the circuit integrity requirements for emergency lighting, communication, and ventilation applications with respect to NFPA 502. | |
|
VITALink® 300 is an RHW-2/RW90 cable, which offers superior fire endurance capabilities along with the well-established benefits and features associated with NEC and CE Code Type RHW-2/RW90 cable designs. It is designed to meet the circuit integrity requirements for emergency lighting, communication, and ventilation applications with respect to NFPA 130. (VT02) | |
|
VITALink® Ethernet Fire Resistive cables are ideal for: • Emergency VoIP communications • IP Area of Refuge communication devices • Addressable Class N fire alarm devices • Critical data communication circuits (VC06) | |
|
VITALink® Fire Resistive CIC cables can be installed either with or without conduit, depending on the application and code requirements. VITALink® CIC cables must be installed as the UL listed FHIT System 40A or FHIT7 System 40A and in accordance with the manufacturer’s installation instructions. These systems require use of specific hardware including conduit, couplings, pulling lubricant, pull boxes, and supports. In areas such as plenum airspace, VITALink® must be installed in conduit. VITALink® CIC cables are ideal for Emergency Voice/Alarm Communication Smoke and Fire Alarm Systems, Fireman’s Telephone and Area of Refuge Communication Systems and Visible Notification Appliances (VC05) | |
|
Rated as both Circuit Integrity (CI) and Circuit Integrity in Conduit (CIC), VITALink® CI/CIC cables can be installed either with or without conduit, depending on the application and code requirements. As CI, also referred to as CI Free Air, VITALink® can be used in riser or horizontal (non-plenum) installations without conduit. The cable must be installed per the NEC code and meet all national and local code requirements. As CIC, VITALink® cable must be installed as the UL listed FHIT System 40A or FHIT7 System 40A and in accordance with the manufacturer’s installation instructions. These systems require use of specific hardware including conduit, couplings, pulling lubricant, pull boxes, and supports. In areas such as plenum airspace, VITALink® must be installed in conduit. (VC04) |
Loading product...