Cable Catalog

Can't find what you need? We'll build it for you.
Catalog Home
Hook-Up Wire
90°C
300 volts
105°C
125°C
Low Voltage
600 volts
150°C
200°C
300 volts
600 volts
450°C
Welding
CLASS K
CLASS M
Multi-Conductor
Unshielded
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Foil Shield
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Braid Shield
Foil/Braid Shield
Standard
Low capacitance
Thermostat
LVT
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
FAT
Data & Communication
Outdoor
Station Z
Solid
Shielded
Unshielded
Stranded
Unshielded
CAT 3
Solid
Shielded
Unshielded
CAT5e
Solid
Shielded
Unshielded
CAT6
Solid
Unshielded
Non-Plenum (FT4)
CAT 3
Solid
Shielded
Unshielded
CAT6a
Solid
Shielded
Unshielded
Station Z
Solid
Unshielded
Intercom
Solid
Unshielded
CAT5e
Solid
Unshielded
CAT6
Solid
Unshielded
Plenum (FT6)
Station Z
Solid
Unshielded
CAT 3
Solid
Unshielded
CAT5e
Solid
Unshielded
CAT6
Solid
Unshielded
L.S.Z.H.
CAT 6
Solid
Unshielded
Fire Alarm Signal
FAS Unshielded
FAS Shielded
FAS Unshielded & Armored
FAS Shielded & Armored
Multi-Pair
Unshielded
Non-Plenum (FT4)
Plenum (FT6)
Shielded
Non-Plenum (FT4)
Overall Foil Shield
Standard
Low Capacitance
Individual Foil Shield
Standard
Low Capacitance
Braid & Individual Foil Shield
Low Capacitance
Foil & Braid Shield
Standard
Low Capacitance
Plenum (FT6)
Overall Foil Shield
Standard
Low Capacitance
Individual Foil Shield
Standard
Low Capacitance
Foil & Braid Shield
Coaxial
Indoor
FT4
FT6
Outdoor
Direct Burial
Aerial
FT1
FT4
Building Automation
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Composites
Datacom
Fiber Optic
Single mode
8,3
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Loose Tube
Outdoor
Multimode
50/125
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
62,5/125
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Loose Tube
Outdoor
2-Hour Fire Rated
Power Cable
Standard
L.S.Z.H.
Approved accessories
FAS
Armored
Shielded
Unshielded
Jacketed
Transit
Power
Mono-conductor
Multi-conductor
Communications
Multi-conductor
Shielded
Unshielded
Multi-pair
Shielded
Unshielded
Emergency circuit
Solar
 
Part # Search
 
Advanced search
Enter criteria

 
Need help?

Ask the Cable Guru

2 Hour Fire Rated

FAS   >   Armored
 
CERCO_FAS_ARM_FA1403 shot
Application
Historical building retrofit
Horizontal and vertical application
 
Description
ULC S-139 with hose stream test
 
14 GA - VITALINK 2 HOUR FIRE RATED WITH HOSE STREAM   EMERGENCY VOICE-ALARM COMMUNICATION
 
Part #Conductor(s)Jacket thicknessSize (AWG)Armor diameterOverall Diameter
CERCO_FAS_ARM_FA14033n/a1417.78 mm17.78 mm
CERCO_FAS_ARM_FA14055n/a1419.81 mm19.81 mm
CERCO_FAS_ARM_FA14077n/a1420.83 mm20.83 mm
14 GA PAIRS - VITALINK 2 HOUR FIRE RATED WITH HOSE STREAM   EMERGENCY VOICE-ALARM COMMUNICATION
 
Part #Pair(s)Jacket thicknessSize (AWG)Armor diameterOverall Diameter
CERCO_FAS_ARM_FA1401P1n/a1415.75 mm15.75 mm
CERCO_FAS_ARM_FA1402P2n/a1421.34 mm21.34 mm
CERCO_FAS_ARM_FA1403P3n/a1422.35 mm22.35 mm
CERCO_FAS_ARM_FA1404P4n/a1423.37 mm23.37 mm
16 GA PAIRS SHIELDED - VITALINK 2 HOUR FIRE RATED WITH HOSE STREAM   EMERGENCY VOICE-ALARM COMMUNICATION
 
Part #Pair(s)Jacket thicknessSize (AWG)Armor diameterOverall Diameter
CERCO_FAS_ARM_FA1601PS1n/a1616.76 mm16.76 mm
CERCO_FAS_ARM_FA1602PS2n/a1626.49 mm26.49 mm
CERCO_FAS_ARM_FA1603PS3n/a1629.34 mm29.34 mm
CERCO_FAS_ARM_FA1604PS4n/a1630.99 mm30.99 mm
16 GA SHIELDED - VITALINK 2 HOUR FIRE RATED WITH HOSE STREAM   EMERGENCY VOICE-ALARM COMMUNICATION
 
Part #Conductor(s)Jacket thicknessSize (AWG)Armor diameterOverall Diameter
CERCO_FAS_ARM_FA1603S3n/a1616.76 mm16.76 mm
CERCO_FAS_ARM_FA1605S5n/a1619.81 mm19.81 mm
CERCO_FAS_ARM_FA1607S7n/a1621.34 mm21.34 mm
Units:  
The values shown are nominal.