Cable Catalog

Can't find what you need? We'll build it for you.
Catalog Home
Hook-Up Wire
90°C
300 volts
105°C
125°C
Low Voltage
600 volts
150°C
200°C
300 volts
600 volts
450°C
Welding
CLASS K
CLASS M
Multi-Conductor
Unshielded
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Foil Shield
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Braid Shield
Foil/Braid Shield
Standard
Low capacitance
Thermostat
LVT
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
FAT
Data & Communication
Outdoor
Station Z
Solid
Shielded
Unshielded
Stranded
Unshielded
CAT 3
Solid
Shielded
Unshielded
CAT5e
Solid
Shielded
Unshielded
CAT6
Solid
Unshielded
Non-Plenum (FT4)
CAT 3
Solid
Shielded
Unshielded
CAT6a
Solid
Shielded
Unshielded
Station Z
Solid
Unshielded
Intercom
Solid
Unshielded
CAT5e
Solid
Unshielded
CAT6
Solid
Unshielded
Plenum (FT6)
Station Z
Solid
Unshielded
CAT 3
Solid
Unshielded
CAT5e
Solid
Unshielded
CAT6
Solid
Unshielded
L.S.Z.H.
CAT 6
Solid
Unshielded
Fire Alarm Signal
FAS Unshielded
FAS Shielded
FAS Unshielded & Armored
FAS Shielded & Armored
Multi-Pair
Unshielded
Non-Plenum (FT4)
Plenum (FT6)
Shielded
Non-Plenum (FT4)
Overall Foil Shield
Standard
Low Capacitance
Individual Foil Shield
Standard
Low Capacitance
Braid & Individual Foil Shield
Low Capacitance
Foil & Braid Shield
Standard
Low Capacitance
Plenum (FT6)
Overall Foil Shield
Standard
Low Capacitance
Individual Foil Shield
Standard
Low Capacitance
Foil & Braid Shield
Coaxial
Indoor
FT4
FT6
Outdoor
Direct Burial
Aerial
FT1
FT4
Building Automation
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Composites
Datacom
Fiber Optic
Single mode
8,3
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Loose Tube
Outdoor
Multimode
50/125
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
62,5/125
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Loose Tube
Outdoor
2-Hour Fire Rated
Power Cable
Standard
L.S.Z.H.
Approved accessories
FAS
Armored
Shielded
Unshielded
Jacketed
Transit
Power
Mono-conductor
Multi-conductor
Communications
Multi-conductor
Shielded
Unshielded
Multi-pair
Shielded
Unshielded
Emergency circuit
Solar
 
Part # Search
 
Advanced search
Enter criteria

 
Need help?

Ask the Cable Guru

Part #CERCO_FAS_CIC_FA1402

Cable Specifications

2-Hour Fire Rated   >   FAS   >   Unshielded
 
 packshot
ULCULCSA
 
Application
EMERGENCY VOICE-ALARM COMMUNICATION
FIREMAN
 
Description
ULC S-139 with hose stream test
Horizontal and Vertical application
 
UL 105°C Type FPL, CM, CL3, PLTC & CSA Type FAS105 C22.2 No. 208
CSA LISTED FAS 105 ST1 FT4
UL 1424 POWER-LIMITED FIRE ALARM CIRCUITS 300 V/105 C
NFPA 79, 72, 130, AND 502
 
Conductors
Number of Pairs1
MaterialCopper
Size (AWG)14
Stranding1
Cabling layen
ConfigurationPair
Number of Conductors2
Color(s)Black/Red
Insulation
Temperature Max.90 °C
MaterialLSZH Thermoset Fire-Roc
Voltage300 Volts
Manufacturer
ManufacturerComtran 36338
Outer jacket
MaterialLSZH Polyolefin
Thickness0.864 mm
ColorRed
Diameter8.941 mm
Temperature Max.90 °C
Options
CSA/UL ApprobationCSA Type FAS105 - ULC S-139
FHIT7 SystemsFHIT7 40A
Characteristics
Overall Diameter8.941 mm
Bending Radius76.2 mm
Weight90.78 kgs/km
Capacitance A*20 pf/m
Conductor Resistance at 20°C2.571 Ohms/km

* Capacitance between conductors
** Capacitance between one conductor and other conductors connected to shield
  Units:
The values shown are nominal.