Cable Catalog

Can't find what you need? We'll build it for you.
Catalog Home
Hook-Up Wire
90°C
300 volts
105°C
125°C
Low Voltage
600 volts
150°C
200°C
300 volts
600 volts
450°C
Welding
CLASS K
CLASS M
Multi-Conductor
Unshielded
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Foil Shield
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Braid Shield
Foil/Braid Shield
Standard
Low capacitance
Thermostat
LVT
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
FAT
Data & Communication
Outdoor
Station Z
Solid
Shielded
Unshielded
Stranded
Unshielded
CAT 3
Solid
Shielded
Unshielded
CAT5e
Solid
Shielded
Unshielded
CAT6
Solid
Unshielded
Non-Plenum (FT4)
CAT 3
Solid
Shielded
Unshielded
CAT6a
Solid
Shielded
Unshielded
Station Z
Solid
Unshielded
Intercom
Solid
Unshielded
CAT5e
Solid
Unshielded
CAT6
Solid
Unshielded
Plenum (FT6)
Station Z
Solid
Unshielded
CAT 3
Solid
Unshielded
CAT5e
Solid
Unshielded
CAT6
Solid
Unshielded
L.S.Z.H.
CAT 6
Solid
Unshielded
Fire Alarm Signal
FAS Unshielded
FAS Shielded
FAS Unshielded & Armored
FAS Shielded & Armored
Multi-Pair
Unshielded
Non-Plenum (FT4)
Plenum (FT6)
Shielded
Non-Plenum (FT4)
Overall Foil Shield
Standard
Low Capacitance
Individual Foil Shield
Standard
Low Capacitance
Braid & Individual Foil Shield
Low Capacitance
Foil & Braid Shield
Standard
Low Capacitance
Plenum (FT6)
Overall Foil Shield
Standard
Low Capacitance
Individual Foil Shield
Standard
Low Capacitance
Foil & Braid Shield
Coaxial
Indoor
FT4
FT6
Outdoor
Direct Burial
Aerial
FT1
FT4
Building Automation
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Composites
Datacom
Fiber Optic
Single mode
8,3
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Loose Tube
Outdoor
Multimode
50/125
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
62,5/125
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Loose Tube
Outdoor
2-Hour Fire Rated
Power Cable
Standard
L.S.Z.H.
Approved accessories
FAS
Armored
Shielded
Unshielded
Jacketed
Transit
Power
Mono-conductor
Multi-conductor
Communications
Multi-conductor
Shielded
Unshielded
Multi-pair
Shielded
Unshielded
Emergency circuit
Solar
 
Part # Search
 
Advanced search
Enter criteria

 
Need help?

Ask the Cable Guru

Part #CERCO_RC90_VM043X0

Cable Specifications

2-Hour Fire Rated   >   Power Cable   >   Standard
 
ULCULCSA
 
Application
Fire Pumps - Emergency Systems - Exhaust & presssurization fans
Fireman's elevator - Emergency Device Activation - Lighting
 
Description
2 Hour Fire Rating ULC S139
CSA Listed Type RC90 per CSA 22.2 No 123
Electrical Circuit Integrity System #120 (FHITC) - ULC
Meet NFPA 130 for Transit and NFPA 502 for Tunnel applications
 
Conductors
MaterialCopper
Size (AWG)3/0
Stranding19
ConfigurationMULTI-CONDUCTOR
Number of Conductors4
Insulation
Temperature Max.90 °C
Temperature Min.-40 °C
MaterialCeramifiable Silicone Rubber
Voltage600 Volts
Manufacturer
NotesVITALINK - VM043X0
ManufacturerRSCC
Inner jacket
Inner Diameter42.672 mm
Armor
TypeWelded copper sheath
ConstructionWelded and corrugated
MaterialCopper
Armor Diameter54.102 mm
Options
CSA/UL ApprobationRC90
ROHSYes
FHIT7 Systems120
Characteristics
Overall Diameter54.102 mm
Bending Radius541.02 mm
Weight5878.39 kgs/km
  Units:
The values shown are nominal.