Cable Catalog

Can't find what you need? We'll build it for you.
Catalog Home
Hook-Up Wire
90°C
300 volts
105°C
125°C
Low Voltage
600 volts
150°C
200°C
300 volts
600 volts
450°C
Welding
CLASS K
CLASS M
Multi-Conductor
Unshielded
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Foil Shield
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Braid Shield
Foil/Braid Shield
Standard
Low capacitance
Thermostat
LVT
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
FAT
Data & Communication
Outdoor
Station Z
Solid
Shielded
Unshielded
Stranded
Unshielded
CAT 3
Solid
Shielded
Unshielded
CAT5e
Solid
Shielded
Unshielded
CAT6
Solid
Unshielded
Non-Plenum (FT4)
CAT 3
Solid
Shielded
Unshielded
CAT6a
Solid
Shielded
Unshielded
Station Z
Solid
Unshielded
Intercom
Solid
Unshielded
CAT5e
Solid
Unshielded
CAT6
Solid
Unshielded
Plenum (FT6)
Station Z
Solid
Unshielded
CAT 3
Solid
Unshielded
CAT5e
Solid
Unshielded
CAT6
Solid
Unshielded
L.S.Z.H.
CAT 6
Solid
Unshielded
Fire Alarm Signal
FAS Unshielded
FAS Shielded
FAS Unshielded & Armored
FAS Shielded & Armored
Multi-Pair
Unshielded
Non-Plenum (FT4)
Plenum (FT6)
Shielded
Non-Plenum (FT4)
Overall Foil Shield
Standard
Low Capacitance
Individual Foil Shield
Standard
Low Capacitance
Braid & Individual Foil Shield
Low Capacitance
Foil & Braid Shield
Standard
Low Capacitance
Plenum (FT6)
Overall Foil Shield
Standard
Low Capacitance
Individual Foil Shield
Standard
Low Capacitance
Foil & Braid Shield
Coaxial
Indoor
FT4
FT6
Outdoor
Direct Burial
Aerial
FT1
FT4
Building Automation
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Composites
Datacom
Fiber Optic
Single mode
8,3
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Loose Tube
Outdoor
Multimode
50/125
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
62,5/125
Tight Buffer
Non-Plenum (FT4)
Plenum (FT6)
Outdoor
Loose Tube
Outdoor
2-Hour Fire Rated
Power Cable
Standard
L.S.Z.H.
Approved accessories
FAS
Armored
Shielded
Unshielded
Jacketed
Transit
Power
Mono-conductor
Multi-conductor
Communications
Multi-conductor
Shielded
Unshielded
Multi-pair
Shielded
Unshielded
Emergency circuit
Solar
 
Part # Search
 
Advanced search
Enter criteria

 
Need help?

Ask the Cable Guru

Building Automation & Control

Plenum (FT6)
 
8272 shot
Application
Building Automation - HVAC
Control
 
Conductors  
 
Part #Conductor(s)Jacket thicknessSize (AWG)Armor diameterOverall Diameter
85668n/a18 AWGn/a6.05 mm
827240.38 mm18 AWGn/a4.93 mm
827540.38 mm22 AWGn/a3.58 mm
830540.38 mm22 AWGn/a3.73 mm
Pairs  
 
Part #Pair(s)Jacket thicknessSize (AWG)Armor diameterOverall Diameter
82581n/a14 AWGn/a5.74 mm
82871n/a16 AWGn/a4.72 mm
826010.38 mm16 AWGn/a4.47 mm
827010.38 mm18 AWGn/a4.01 mm
827330.25 mm18 AWGn/a6.99 mm
828010.38 mm18 AWGn/a4.06 mm
828220.38 mm18 AWGn/a6.25 mm
829010.38 mm20 AWGn/a3.51 mm
829310.38 mm22 AWGn/a3.1 mm
830010.38 mm20 AWGn/a3.56 mm
830210.38 mm22 AWGn/a4.72 mm
8302R110.38 mm22 AWGn/a0.19 mm
832010.38 mm24 AWGn/a3.71 mm
8320.51.50.38 mm24 AWGn/a4.72 mm
832120.38 mm24 AWGn/a5.79 mm
83234n/a24 AWGn/a4.57 mm
Triads  
 
Part #Triad(s)Jacket thicknessSize (AWG)Armor diameterOverall Diameter
826110.38 mm16 AWGn/a4.98 mm
827110.38 mm18 AWGn/a4.27 mm
827410.25 mm22n/a6.99 mm
828110.38 mm18 AWGn/a4.47 mm
829110.38 mm20 AWGn/a3.71 mm
830410.38 mm22 AWGn/a3.43 mm
8304R10.38 mm22 AWGn/a5.03 mm
Units:  
The values shown are nominal.