Home
français
 
 
  • ULC - 2 hour fire rating
  • Approved for Canada
  • Certified for use FHIT/FHITC 40A systems
  • Vertical and horizontal installations


 
VITALink®Cable is designed to support Life and Fire Safety. This cable offers “survivability” for 2-Hours in harsh environments while being fully operational to allow for safe evacuation of building occupants. It has achieved FPL, CMG, CL3 & PLTC rating and has been re-certified under the new UL 2196 guidelines for 2-hour fire resistive cables for use in system FHIT.40A and FHITC.40A. In addition, the cable is certified for use in Canada as a c(UL) CMG listed cable and CEC Type FAS 90.
 
Description
  • 14 AWG / 16 AWG 2 Conductors Shielded 2-Hour Fire Rated
  • UL Listed FPL-LS
  • CMG, CL3, PLTC, c(UL) CMG, & CSA FAS 90
  • cable ANSI/UL 2196
  • Certified for use in System FHIT.40A
  • CAN/ULC-S139 with Hose Stream for use in System FHITC.40A
  • 12 AWG / 14 AWG / 16 AWG and 18 AWG 2 conductors unshielded
  • UL 105°C listed Type FPL, CM, CL3, PLTC and CSA FAS 90
  • UL Fire Resistance Directory R27557 (72V)
Compliance
  • CAN/ULC-S139 Certified with Hose Stream Test for use in FHITC system 40A
  • NEC type FPL, CMG, CL3 & PLTC for use in Electrical Circuit Integrity System FHIT 40A
  • C(UL) listed CMG
  • CEC and CSA listed FAS90 to C22.2 No. 208-14
  • UL Certified to ANSI/UL 2196 2-Hour fire rating for use in FHIT system 40A. (See UL Fire Resistance Directory R27557)
  • UL 1424 Listed FPL-LS for Power-Limited Fire Alarm Cables; 300V / 105°C
  • UL 13 Listed CL3 & PLTC for Power-Limited Circuit Cables; 300V / 105°C
  • UL 444 Listed CMG for Communication Cable; 300V / 105°C
  • Fire certified for power-limited system use at 72V phase-to-phase utilization voltage
 
Hardware certified
  • ½", ¾", 1", 1 ½", and 2" EMT Conduit “E-Z Pull”– Allied Tube & Conduit Co. and Columbia MBF
  • ½", ¾", 1", 1 ½", and 2" Steel Compression Couplings – RACO or Thomas & Betts Corp.
  • Wiegmann NEMA 1 Enclosure/Pull Box
  • Amtec wire mesh support grips for vertical installation beyond 45 feet
  • Supports per the Comtran Cable’s installation instructions dated June, 2016
  • American Polywater – Type LZ – pulling lubricant
Applications
  • (EVAC) Emergency Voice-Alarm Communication Smoke and Fire Alarm Systems
  • Fireman’s Telephone and Area of Refuge Communication Systemsc
  • Emergency Lighting
  • Manufacturing, Commercial and Industrial Locations
  • Colleges, Banks, Hotels, Airports and Stadiums
  • Health Care Facilities
  • Tunnels and Subways for Emergency Communications
 
Notice: Product must be installed according to the FHITC 40A installation manual with the certified hardware.